top of page
INDUSTRIAL LTD

© 2026 Lias Industrial | All rights reserved

Phone

+44 (0) 1204 594941

Address
2 John Street, Bromley Cross, Bolton BL7 9BA

Related Products

Phoenix 85 Series Scanner | SIL3

The Fireye Phoenix Series 2 type 85UVF/IRF flame scanners, designed for reliable flame detection in burner management systems. These microprocessor-based devices utilise a solid-state flame detection sensor, ensuring precise and consistent performance. The Phoenix flame scanners incorporate an internal flame relay with automatically set ON/OFF thresholds, eliminating the need for a remote flame amplifier or flame switch. Built to meet SIL3 safety standards, these scanners deliver dependable protection and operational efficiency. 

 

For a complete system you will also need:

 

Mounting Flange

Cable

Swivel Mount

Certificate

Part Numbers

85IRF1A-1QD

Phoenix Series II Scanner, selectable FFRT - Infrared, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 60-2692, 60-2919 mounting flange.

85IRF4A-1QDWR

Phoenix Series II Scanner, Selectable FFRT - Infra-red, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC, or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 60-2692, 60-2919 mounting flange.

85UVF1A-1QD

Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 60-2692, 60-2919 mounting flange.

85UVF1A-1QDK3

Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect and K3 filter. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 60-2692, 60-2919 mounting flange.

85UVF4A-1QDK3WR

Phoenix Series II Scanner, Selectable FFRT - Ultra-violet, with quick disconnect and K3 filter. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 60-2692, 60-2919 mounting flange.

85UVF4A-1QDWR

Phoenix Integrated Scanner, Selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 60-2692, 60-2919 mounting flange.

PHOENIX SERIES II FIBER OPTIC FLAME SCANNERS

85IRF1A-2QD

Fiber-optic version of Phoenix Series II Scanner, selectable FFRT - Infrared, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 61-7443 fiber optic assemblies.

85IRF4A-2QDWR

Fiber optic version of Phoenix Series II Scanner, Selectable FFRT - Infrared, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 61-7443 fiber optic assemblies.

85UVF1A-2QD

Fiber-optic version of Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 61-7442 fiber optic assemblies.

85UVF1A-2QDK3

Fiber-optic version of Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect and K3 filter.. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 61-7442 fiber optic assemblies.

85UVF4A-2QDK3WR

Fiber optic version of Phoenix Series II Scanner, Selectable FFRT - Ultra-violet, with quick disconnect and K3 filter. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 61-7442 fiber

85UVF4A-2QDWR

Fiber optic version of Phoenix Series II Scanner, Selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 61-7442 fiber optic assembl

PHOENIX EXPLOSION PROOF SCANNERS

60-2780-1

Replacement scanner for 85UVF1-1CEX. NOT FOR SALE IN US.

60-2780-3K3

Replacement scanner for 85UVF1-1CEX-K3. NOT FOR SALE IN US.

60-2780-5

Replacement scanner for 85IRF1-1CEX. NOT FOR SALE IN US.

85IRF1-1CEX

Cenelec EExd IIC explosion proof housing with 85IRF1-1 scanner. CE Approved. NOT FOR SALE IN US

85IRF1-1CEX2

Cenelec EExd IIC T6, ATEX approved housing, dual threaded cable entries with 85IRF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US

85UVF1-1CEX

Cenelec EExd IIC T6, ATEX approved housing with 85UVF1-1 scanner. CE Approved. Mounting flange ordered separately. NOT FOR SALE IN US

85UVF1-1CEX2

Cenelec EExd IIC T6, ATEX approved housing, dual threaded cable entries with 85UVF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US

85UVF1-1CEXK3SS

Cenelec EExd IIC T6, ATEX approved Stainless Steel housing, dual threaded cable entries with 85UVF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US

85UVF1-1CEXSS

Cenelec EExd IIC T6, ATEX approved Stainless Steel housing, dual threaded cable entries with 85UVF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US

85UVF1-1CEX-K3

Cenelec EExd IIC T6, ATEX approved housing with 85UVF1-1K3 scanner. CE Approved. Mounting flange ordered separately. NOT FOR SALE IN US

bottom of page