The Fireye Phoenix Series 2 type 85UVF/IRF flame scanners, designed for reliable flame detection in burner management systems. These microprocessor-based devices utilise a solid-state flame detection sensor, ensuring precise and consistent performance. The Phoenix flame scanners incorporate an internal flame relay with automatically set ON/OFF thresholds, eliminating the need for a remote flame amplifier or flame switch. Built to meet SIL3 safety standards, these scanners deliver dependable protection and operational efficiency. 

 

For a complete system you will also need:

 

Mounting Flange

Cable

Swivel Mount

Certificate

Part Numbers

85IRF1A-1QD Phoenix Series II Scanner, selectable FFRT - Infrared, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 60-2692, 60-2919 mounting flange.
85IRF4A-1QDWR Phoenix Series II Scanner, Selectable FFRT - Infra-red, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC, or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 60-2692, 60-2919 mounting flange.
85UVF1A-1QD Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 60-2692, 60-2919 mounting flange.
85UVF1A-1QDK3 Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect and K3 filter. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 60-2692, 60-2919 mounting flange.
85UVF4A-1QDK3WR Phoenix Series II Scanner, Selectable FFRT - Ultra-violet, with quick disconnect and K3 filter. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 60-2692, 60-2919 mounting flange.
85UVF4A-1QDWR Phoenix Integrated Scanner, Selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 60-2692, 60-2919 mounting flange.
PHOENIX SERIES II FIBER OPTIC FLAME SCANNERS
85IRF1A-2QD Fiber-optic version of Phoenix Series II Scanner, selectable FFRT - Infrared, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 61-7443 fiber optic assemblies.
85IRF4A-2QDWR Fiber optic version of Phoenix Series II Scanner, Selectable FFRT - Infrared, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 61-7443 fiber optic assemblies.
85UVF1A-2QD Fiber-optic version of Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 61-7442 fiber optic assemblies.
85UVF1A-2QDK3 Fiber-optic version of Phoenix Series II Scanner, selectable FFRT - Ultra-violet, with quick disconnect and K3 filter.. Use 59-546-xx cable. FM, UL/c, CE Approved. Uses 61-7442 fiber optic assemblies.
85UVF4A-2QDK3WR Fiber optic version of Phoenix Series II Scanner, Selectable FFRT - Ultra-violet, with quick disconnect and K3 filter. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 61-7442 fiber
85UVF4A-2QDWR Fiber optic version of Phoenix Series II Scanner, Selectable FFRT - Ultra-violet, with quick disconnect. Use 59-546-xx cable. For use with EDC1, EDC2, MEDC2, YB110DC or YB230DC direct coupled amplifiers. FM, UL/c Approved. Uses 61-7442 fiber optic assembl
PHOENIX EXPLOSION PROOF SCANNERS
60-2780-1 Replacement scanner for 85UVF1-1CEX. NOT FOR SALE IN US.
60-2780-3K3 Replacement scanner for 85UVF1-1CEX-K3. NOT FOR SALE IN US.
60-2780-5 Replacement scanner for 85IRF1-1CEX. NOT FOR SALE IN US.
85IRF1-1CEX Cenelec EExd IIC explosion proof housing with 85IRF1-1 scanner. CE Approved. NOT FOR SALE IN US
85IRF1-1CEX2 Cenelec EExd IIC T6, ATEX approved housing, dual threaded cable entries with 85IRF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US
85UVF1-1CEX Cenelec EExd IIC T6, ATEX approved housing with 85UVF1-1 scanner. CE Approved. Mounting flange ordered separately. NOT FOR SALE IN US
85UVF1-1CEX2 Cenelec EExd IIC T6, ATEX approved housing, dual threaded cable entries with 85UVF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US
85UVF1-1CEXK3SS Cenelec EExd IIC T6, ATEX approved Stainless Steel housing, dual threaded cable entries with 85UVF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US
85UVF1-1CEXSS Cenelec EExd IIC T6, ATEX approved Stainless Steel housing, dual threaded cable entries with 85UVF1-1 scanner. CE Approved. Mounting flange and locknut (33-498) ordered separately. NOT FOR SALE IN US
85UVF1-1CEX-K3 Cenelec EExd IIC T6, ATEX approved housing with 85UVF1-1K3 scanner. CE Approved. Mounting flange ordered separately. NOT FOR SALE IN US