top of page
INDUSTRIAL LTD

© 2026 Lias Industrial | All rights reserved

Phone

+44 (0) 1204 594941

Address
2 John Street, Bromley Cross, Bolton BL7 9BA

Related Products

Forney IDD Flame Scanner

Forney’s Intelligent Dynamic Detector (IDD) II series is designed to accurately detect and discriminate the luminous flames produced by burning oil, coal, and lignite fuels.

Product Overview

The IDD-II (Filtered) flame detector is typically used for sensing heavy fuel oil and coal flames. The IDD-IIU (Unfiltered) flame detector is typically used for sensing light fuel oil flames. The IDD-IIL (Lignite) flame detector is specifically designed to sense low flame frequency produced by lignite and high ash coal flames.

The IDD-II Series is used in conjunction with Forney’s supporting amplifiers IDD-9000, DR-6101E, RM-IDD and IDD-IIIA.

The IDD-II’s solid state circuitry amplifies a continuously changing voltage signal transmitted from the lead sulfide sensor when flame is sensed. The signal is then sent to the amplifier by way of a four conductor cable. The amplifier processes the signal and provides outputs to the burner management system.

For trouble-free operation, the detector electronics are potted within the cast steel housing. In addition, the amplifier also initiates a periodic, electronic selfcheck of the sensor and printed circuit board to verify proper operation of the detector assembly.

Technical Data

Products and Accessories:

IDD-II Infrared Detector

Filtered (#6 Oil & Coal )

Part #38321-21

IDD-IIU Infrared Detector

Unfiltered (#2 Oil, #6 Oil & Coal)

Part #38321-22

IDD-IIL, Infrared Detector

Lignite Fuel

Part #38321-23

Cooling Chamber (optional)

 

Part #381071-01

 

Specifications:

Mounting:

1” NPT sight pipe fitting

Materials:

Cast Steel Housing, Potted Electronics

Electrical:

Supplied by Amplifier, 50 VDC and 12 VDC

Electrical Connections:

MS Bayonet connector supplied with cable, 1/2” flexible conduit required

Cooling Air Requirements:

Front mount applications – minimum cooling air flow of 10 scfm (17 m3/hr) at a maximum temperature of 120°F (48°C) Fiber optic applications – minimum cooling air flow of 15 scfm (25 m3/hr) at a maximum temperature of 120°F (48°C)

Temperature Ratings:

32°F to 140°F (0°C to 60°C)

With Cooling Chamber:

For ambient temperatures of 140°F to 200°F (60°C to 93°C) the Forney Cooling Chamber must be used.

Humidity:

0-95% relative humidity, non-condensing

Shipping Weight:

21 oz

Approvals:

Factory Mutual (FM)

Sensor / Wavelength:

IDD-IIU 400 – 3300nm IDD-II 700 – 3300nm IDD-IIL 700 – 3300nm (The IDD-IIL detector has better flame flicker frequency response at lower flicker frequency ranges of >5 to 18 Hz)

Resources

Detector Heads

  • IDD-II Technical Bulletin Publication #404005-05

  • UV-4 Detector Technical Bulletin Publication #404005-17

 

Amplifiers

  • IDD 9000 Amplifier Technical Bulletin Publication #404005-21

  • RM-IDD & PM-IDD IIIA Amplifier Technical Bulletin Publication #404005-16

  • DR6101E Amplifier Technical Bulletin Publication#404005-07

 

Cooling Chambers

  • IDD Cooling Chamber Technical Bulletin Publication #404005-18

  • UV-4 Cooling Chamber Technical Bulletin Publication #404005-20

Benefits

  • Lead Sulfide Sensor Sensitive to infrared and visible light radiation prevalent in fuel oil, coal and lignite flames.

  • Dynamic Flame Sensing Circuitry Senses only a dynamic flame signal, discriminates flame from hot refractory and other background conditions.

  • Compact, Durable Assembly The printed circuit board and sensor are potted within a cast steel housing providing a maintenance free product.

  • Simplified System maintenance Quick disconnect, electrical and mechanical connections are used for easy replacement.

  • Fiber Optics Optional fixtures are available for fiber optic applications.

  • Factory Mutual Approval Factory Mutual (FM) approval means safe operation and lower insurance rates.

bottom of page