© 2026 Lias Industrial | All rights reserved
Phone
+44 (0) 1204 594941
Address
2 John Street, Bromley Cross, Bolton BL7 9BA
Related Products






Fireye | BurnerPRO
Low cost burner control for new installations and Siemens LFL / LGK replacement. Use existing base.
Can replace Honeywell/ Satronic TMG. Rewire required
Order 60-2981-1 base separately for new installations
Can use any of the following flame scanners:
Product Info
ADD NEW FUNCTIONALITY TO BURNERS WITH THE SIEMENS LFL OR LGK INSTALLED. THE FIREYE BURNERPRO OPERATES AND CONTROLS YOUR BURNER THE SAME WAY AS YOUR LFL OR LGK DOES BUT WITH THE ADDED BENEFIT OF:
- Smart LED's showing current burner state
- 62 different lockout codes using the LED's to tell you exactly what the problem is so you can fix it quicker.
- Run / Check feature to allow the cycle to pause in the ignition, pilot or main timings. this allows easier commissioning and fault finding
- In check mode the LED's become a flame strength meter. This allows for aiming of the UV cell or realignment of the ionisation probe
- Built in self checking circuit for ionisation rod, this upgrades your burner to >24hr continuous use.
The Fireye BurnerPRO is a compact, microprocessor based, primary flame safeguard control system designed to provide the proper burner sequencing, ignition and flame monitoring for on-off, multi-stage, or modulating burners used in commercial heating and process equipment firing oil and gas fuels. The BurnerPRO flame safeguard offers two built-in amplifiers, which allows for use in UV only, FR only, and UV+FR applications. Flame monitoring for UV is accomplished by using available UV scanners: UV90L & UV1AL. Flame monitoring for FR version is accomplished by using available ionisation rod: 69ND1.
The FR amplifier circuitry is subjected to permanent self-checking, which allows it for use in applications that require burner cycle that runs for more than 24 hours. When operated as a UV control, the system is considered non-permanent, which requires a burner recycle at least once every 24 hours. Control functions and timings are factory set via unique micro-controller firmware. Through seven SMART LEDs, the control provides current operating status and lockout information in the event of a safety shutdown. Refer to the BurnerPRO ordering information section in this document for the various combinations of control functions and timings.
A complete BurnerPRO system includes the BP110/230, flame scanner and wiring base. The BurnerPRO performs a safe-start check on every burner cycle. If flame is detected prior to a start or during the purge cycle, the fuel valves are not energised and the control locks out. The ‘POC’ input is also monitored to verify that the main fuel valves are always in the proper state prior to the start of a burner cycle. The LEDs & alarm terminal are used to annunciate the presence of a lockout condition.
Expanded functions of the BurnerPRO:
-
Non-volatile lockout capability
-
Proof of fuel valve closure
-
Air-flow proving
-
A run/check feature allows the operator to stop the program sequence in different positions (Purge, Ignition, PTFI and MTFI) for system troubleshooting
-
Remote and local Reset
-
Two built-in amplifiers (UV, FR, UV+FR) for flexibility in applications
-
Smart LEDs provide on board diagnostic lockout information
-
Real-time internal diagnostics for added safety integrity
-
Extended temperature operation (-40°C to 60°C) with an over-temp inhibit feature
-
High capacity relay contacts
PDF Manuals
Certificates
Specifications
Supply Voltage:
BP110 110 VAC (+20%, -15%) 50/60 Hz, single phase
BP230 230 VAC (+10%, -15%) 50/60 Hz, single phase
Power Consumption:
7 VA
Temperature Rating:
Operating: -40°C to +60°C (-40°F to 140°F)
Storage: -50°C to +85°C (-58°F to 185°F)
Flame Amplifier Rating:
UV: Terminals 22 & 23, 300VDC 3mA(max)
FR: Terminals 24 & Earth, 330VAC (max), 3uA min/10uA max flame current
Protection Category:
IP40 standard version (with exception of wiring base)
IP44 for “F” version
Control Dimensions:
With wiring base (60-2944-1); 4.15” L x 4.15" W x 5.0" H (105mm x 105mm x 127mm)
Shipping Weight:
Approx. 2.5 lbs. (1.13kg)
Part Numbers 110V Standard
| BP110UVFR-S1 | BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 1 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S2 | BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 2 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S3 | BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 3 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S5 | BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 5 timings (S3 timings with 4 sec FFRT), with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
Part Numbers 110V Modbus
| BP110UVFR-S11M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7800 for use with 60-2991-1. , Default timings: Purge = 30 sec, PTFI = 10 sec, MTFI = 10 sec. UV non-self check and FR amplifier, IP40. |
| BP110UVFR-S12M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7800 for use with 60-2991-1. , Defauts timings: Purge = 30 sec, PTFI = 10 sec, MTFI = 15 sec. UV non-self check and FR amplifier, IP40. |
| BP110UVFR-S13M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7895 for use with 60-2991-2. , Default timings: Purge = 5 sec, PTFI = 5 sec, MTFI = 10 sec. UV non-self check and FR amplifier, IP40. |
| BP110UVFR-S14M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Timings to replace Honeywell RM7895 for use with 60-2991-2. , Default timings: Purge = 5 sec, PTFI = 10 sec, MTFI = 15 sec. UV non-self check and FR amplifier, IP40. |
| BP110UVFR-S1M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 1 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S2M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 2 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S3M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 3 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S4M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 4 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S5M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 5 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S6M | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Series 6 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-SXM | BurnerPRO Single Burner Control with ModBus, 110VAC 50/60Hz, Flexible Series timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
Part Numbers 110V Modbus with Valve Proving
| BP110UVFR-S1MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 1 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S2MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 2 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S3MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 3 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S4MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 4 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S5MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 5 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-S6MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Series 6 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP110UVFR-SXMP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 110VAC 50/60Hz, Flexible Series timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
Part Numbers 230V Standard
| BP230UVFR-S1 | BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 1 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S2 | BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 2 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S3 | BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 3 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
Part Numbers 230V Modbus
| BP230UVFR-S1M | BurnerPRO Single Burner Control with ModBus, 230VAC 50/60Hz, Series 1 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S2M | BurnerPRO Single Burner Control with ModBus, 230VAC 50/60Hz, Series 2 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S3M | BurnerPRO Single Burner Control with ModBus, 230VAC 50/60Hz, Series 3 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S4M | BurnerPRO Single Burner Control with ModBus, 230VAC 50/60Hz, Series 4 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-SXM | BurnerPRO Single Burner Control with ModBus, 230VAC 50/60Hz, Flexible Series timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
Part Numbers 230V Modbus with Valve Proving
| BP230UVFR-S1MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 1 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S2MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 2 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S3MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 3 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-S4MP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Series 4 timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
| BP230UVFR-SXMP | BurnerPRO Single Burner Control with ModBus and Valve Proving, 230VAC 50/60Hz, Flexible Series timings, with UV non-self check and FR amplifier, IP40. Compatible with 60-2981-1 and Siemens LFL wiring base |
Part Numbers Wiring Bases
| 60-2981-1 | Open base with terminal block and PG11 knockouts w/ grounding leash, 4.1”L x 4.1”W x 1.2”H. |
| 60-2981-M16 | Open base with terminal block and M16 knockouts w/ grounding leash, 4.1”L x 4.1”W x 1.2”H. |
| 60-2991-1 | Wiring harness to convert RM7800 / RM7840 / RM7845 (less valve proving) to Fireye BurnerPRO. |
| 60-2991-2 | Wiring harness to convert RM7895 to Fireye BurnerPRO. |
| 61-7429-1 | Grounding leash |